Your said setting is 21 and it shuts off at 19. Does it happen each time after you reset?
If it does shuts off at 19 every time, I Suggest you to do a simple test. change the setting up to 23, make a note of the temperature reading when it shuted off, if it shut off at 19 again, it most likely the over temperature thermostat protection switch beside the burner compartment is not working properly,(Burner compartemant is too hot before the room temperature reachs to the setting) if it shut off at 23 or higher, the temperature controller may have problem, remove battery to reset the controller, if you can also remove all the wires that connected to the controller. Good Luck!
Report

Replies, comments and Discussions:

  • 枫下家园 / 美丽家居 / 暖气炉于近日故障:调到21度,19度就停。如果关掉温控器重开又能启动。请教大师们怎么办啊?先谢
    • 如果是机械式的,有可能里面的水银泡位置变动,导致指针位置偏移,看着是21,实际是19。
      • 数字式的,重开温控器后可以启动,但是过一会就会停。然后需要重开温控器才又启动。会不会是炉子坏了?可是重开温控器可以启动啊。
        • 如果炉子一次启动工作时间短于4分钟的话,发生故障的可能性比较大。你能看见炉子里面燃烧着吗?
        • 启动不等于炉子燃烧工作。一般温控器指令炉子供热时,最先启动的是风机和排烟风扇。而实际不一定点火燃烧。你先到炉子旁边打开盖子,看看里面有没有燃烧发生?
          • 有火。而且吹出来的热风一点不比原来差。只是提前停掉。
            • 那就很可能 是机器本身的问题了may be self protection
            • 有温度计吗?对比一下温度计上的显示温度,看温控器的指示准不准.或者把温度调高到23度,看炉子多少度停。
              • 我这次开到23度了,已经工作30分钟还在工作,室温已达21度了。看来时温控器的问题?谢谢你
                • 温控器不准的可能较大了。最好用温度计再校一下为好。
                  • 第一次我发现停,室温已经·18度了(我要的21度),现在工作近一小时了室温22度(调的23度)还在工作。是不是还不只是不准?
                    • 温度计,温度计,温度计.......:-(
          • 炉子从启动到停止工作,多少时间?
            • 不一定,好像跟调到多高有关系。
    • check the filter. It happend to me. The filter is too dirty
      • 谢谢
    • 小意见
      Your said setting is 21 and it shuts off at 19. Does it happen each time after you reset?
      If it does shuts off at 19 every time, I Suggest you to do a simple test. change the setting up to 23, make a note of the temperature reading when it shuted off, if it shut off at 19 again, it most likely the over temperature thermostat protection switch beside the burner compartment is not working properly,(Burner compartemant is too hot before the room temperature reachs to the setting) if it shut off at 23 or higher, the temperature controller may have problem, remove battery to reset the controller, if you can also remove all the wires that connected to the controller. Good Luck!
      • 不是总停在19度,第一次我发现停,室温已经·18度了(我要的21度),现在工作近一小时了室温22度(调的23度)还在工作。温控器里有电池吗?我试试拆掉所有的线再装回去?
        • 跟电池与线路无关。只要风机与燃烧同步,没有异味出来,说明炉子本身工作是正常的。只是温控器最可疑。另外,随着设定温度的不同,停机温度也不同,这说明炉子反应与温度设置同步。如果可能的话,换个温度器看看。
        • 炉子是高效的还是普通的?多大房子?炉子多少年了?
          • 高效的。carrier的,11年了。房子不大但分开楼层装了两个。
            • 多大的房子啊。也不答全?fnt...
            • 分开两个是什么东西?是温控器?
              • 两个高效炉分开来两层楼,2500尺+地下室
                • 2500sf,不小了。可两个炉子一起工作的话,从19度升到23度,应该用不了1个小时的。
        • 所有电子数字温控器里都有兩枚笔芯电
    • 谢谢楼上两位同学,我后来调到22度,机器没在停又好了。请问问无牌电工遥控·器内纽扣电池多久需要换?
      • what kind of controller is ? modle #? brand?
        each controller may be different. my controller use two double AA battery, have message display, saying Low battery, i don't need to do any thing till message is display, which rouguly every two year on my system
        google your controller model on line to get more info,